Responsible: Juan Carlos Miangolarra Page Address: Avda. Atenas s/n. 28922 Alcorcón Dpal II Building, 1st Floor Department: Physiotherapy, Occupational Therapy, Rehabilitation and Physical Medicine Phone: 914 888 913 914 888 913. Fax: 914 888 957 Website: https://lambecom.webnode.es |
Essays/Services offered
Analysis of gait, movement or ergonomics
- Especially gait in neurological, musculoskeletal, degenerative, vascular and diabetic pathology including amputation, sports or footwear origin. Diagnosis of gait disorders.
- Assessment of bodily harm and disability (expert reports on work accidents, traffic accidents, assaults in criminal acts, civil liability, disability, social services, professional negligence).
- Applicability and functional study of orthotic and prosthetic devices and support products (upper and lower limbs): evaluation, efficacy and adaptation.
- Assessment of bodily harm and disability (expert reports on work accidents, traffic accidents, assaults in criminal acts, civil liability, disability, social services, professional negligence).
- Fall risk detection.
posturography analysis
- Balance analysis and diagnosis of balance disorders.
Surface electromyography report
- Electromyographic records. Study functionality.
Processing of gait, movement or ergonomics analysis tests.
Others
- Evaluation of work performance, ergonomics and neuro-muscular response.
- isokinetic response.
- Evaluation and study of muscle strength. Joint assessment.
- Evaluation of the effectiveness of training programs, rehabilitation and any medical or surgical therapeutic intervention. Pre- and post-: botulinum toxin, neuromotor, reconstructive, functional and functional orthopedic surgery and arthroplasty.
- Detection of simulators / psychogenic disorders.
laboratory staff
Scientific Manager Juan Carlos Miangolarra Page |
Category University Professor of Physical Medicine and Rehabilitation. Head of the Clinical Service of Physical Medicine and Rehabilitation of the University Hospital of Fuenlabrada |
Technical staff |
Category |
Roberto Cano de la Cuerda |
Profesor Titular de Universidad |
Francisco Molina Rueda |
Profesor Titular de Universidad |
Marta Perez de Heredia Torres |
Profesora Titular de Universidad |
Isabel Maria Sheriff Diego |
Hired Professor Doctor |
Maria Carratala Tejada |
Hired Professor Doctor |
Alicia Cuesta Gomez |
Hired Professor Doctor |
Patricia Sanchez-Herrera Baeza |
Hired Professor Doctor |
Alberto Molero Sanchez |
Associate professor |
Pilar Fernandez Gonzalez |
Visiting Professor |
Maria Dolores Vialas Gonzalez |
Laboratory technician |
Diego Fernandez Vazquez |
Predoctoral researcher |
Victor Navarro Lopez |
Predoctoral researcher |
Available equipment
VICON photogrammetry equipment |
|
MX13+ infrared cameras |
8 |
AMTI Platforms |
3 |
BASLER A601FC-2 color cameras |
2 |
MX-Ultranet Hub |
2 |
MX-Control Controller |
1 |
Full manufacturer reference documentation |
|
Unlimited Oxford Metrics support |
|
Clinical gyroscopes (IMUs) |
ZeroWire Cometa Electromyography Equipment |
|
16 channel receiver |
2 |
Full manufacturer reference documentation |
-
Vision Cameras |
|
AXIS |
4 |
POE-SWITCH |
1 |
Full manufacturer reference documentation |
-
computerized posturography equipment |
|
NUEROCOM SMART EQUITEST |
1 |
tetrax |
1 |
Full manufacturer reference documentation |
-
Electrogoniometry, electromyography and podobasography equipment. |
|
STEP 32 |
1 |
Full manufacturer reference documentation |
-
Stochastic vibrating platform equipment. |
|
Fepping |
1 |
Full manufacturer reference documentation |
-
Isokinetic evaluation equipment. |
|
Biodex System 3 (830-450). Biodex Medical Systems. |
1 |
Full manufacturer reference documentation |